Seismic detectors
- for Safes ATMs' & Vault DoorsDistributed by SecuraCorp International Pty. Ltd.
Senstec Seismic Detectors GM530
New Senstec bimorph sensor technology for:
- Optimum response to all known attack tools
- Maximum immunity to environmental interference Signal analysis which has been designed to be independent
of airborne sound enables mounting of the detector to the
inside as well as the outside surface of the object to be
protected, without the problem of false alarms Universal application allows for 24 Hour monitoring on:
- Safes & Night safes
- Strongrooms - Strongroom doors
- Automatic cash dispensers (ATMs') Integrated self-test system rapidly checks for correct
operation of the electronics and of the Senstec sensor Maximum performance is guaranteed, regardless of
mounting pressure, thanks to the new Senstec sensor
and signal evaluation technology
-
Dip switches for programming to site conditions :
- Adjustable sensitivity - 4 levels
- Response time adjustable - 2 settings
- Shock setting for concrete or steel - 3 levels Full protection against electrical interference:
- Metal encapsulation to shield from electromagnetic interference fields
- Efficient filter circuits as a safeguard against conducted interference Designed for ease of installation:
- Electric connections and mounting screws are readily accessible
- Electronics protected against accidental contact
-
The Senset GM530 detector is suitable for the
detection of all known types of attacks on
steel or concrete objects.
Any attacks carried out by means of
explosives, diamond-bit drills, mechanical
devices or thermic tools such as cutting torches
and oxygen lances are immediately and reliably detected.

Condensed Technical specifications
Frequency range - 13Kh to 19k Kh Special circuitry makes the unit immune to airborne noise Self test system allows testing of detector Can be mounted inside & outside container. Operating radius on Concrete & Steel:
- All tools (including thermic) - 3Meters
- Mechanical tools - 6Meters in-built tamper monitoring Power - 7 to 16V DC Current - Normal 3.5mA (Alarm -5.0mA) Alarm output - changeover relay Hold time for alarm - approx 2.5secs Operate temperature -20 to +60 C Humidity - to class F (<95%RH) Various mounting plates supplied
- wall, floor, recessed Size - 89 X 89 mm, 22mm thick Weight - detector & mount - 0.6Kg